MODEL 1001 IN-DUCT HEPA FAN-FILTER*
Ultra Energy Efficient Series

Engineering/Application Data
 

 Submittal Dwgs-   Overall       (Printable Version- )

  Inlet Connection                  Outlet Connection

   (Printable Version- )                       (Printable Version- )

 
  • Ultra Low Pressure Drop HEPA filter – 0.6” WC @ 2000 scfm.

  • Built in ASHRAE 30% Filter unit.

  • High External Static Pressure capability.

  • Available with or without built in fan.

  • The most energy efficient air driver in the industry

  • Ultra Quiet Operation

  • For ISO Class 1 – 5,  4 to 6 terminal ceiling HEPA filters per Model 1001 are recommended – resulting in system filtration efficiency of at least 99.999999% @0.1 –0.3 Um.

  • For Class 6 and above - no terminal HEPAs are necessary –8 2x2 diffusers per Model 1001 ceiling diffusers are recommended

FEATURES/ BENEFITS
  • Inhibits Bacterial** Growth - Lower BIOBURDEN

  • Small size/lower weight - easily installs in ceiling space- Lower installation cost.

  • Independent flow velocity/distribution control - supply where needed - higher effectiveness

  • Quick filter changes done outside room - No contamination during filter changes

  • Connects to conventional A/C units - low weight- Lower initial cost - roof reinforcements may not be required

  • No plenum required - leaks eliminate

  • Remote ON-OFF, control/ indicators - Ease of control and monitoring

  • Easily ducted for negative pressure - Ideal for hospital and other isolators

SPECIFICATIONS

Height 26” – 66 cm
Width  26” – 66 cm
Length 30” –76.2 cm

AVAILABLE WITH STANDARD REMOTE CONTROLLER

ALL UNITS CAN OPERATE AT 230/380/400/440/460 VAC – 50 OR 60 Hz
1001 MODELS FLA CBA HP FLOW (scfm)
Model# Power   60Hz 50 Hz   60 Hz 50 Hz 60 Hz 50 Hz
1001-A-1 120VAC, 1-PHASE, 50/60 Hz   0.18 0.2 2 N/A N/A 3000(4) 3000(3)
1001-A-2 230VAC, 1-PHASE, 50/60 Hz   0.35 0.4 2 N/A N/A 3000(4) 3000(3)
1001-B-1 208-230VAC, 3-PHASE, 50/60 Hz   2.6 2.1 5 1.07 0.78 2500 2100
1001-B-2 440-460VAC, 3-PHASE, 50/60 Hz   1.5 1.45 5 1.07 0.78 2500 2100
1001-B-3 380-400VAC, 3-PHASE, 50 Hz   N/A 1.4 5 N/A 0.69 2100 1775
1001-B-4 230VAC, 1-PHASE, 50/60 Hz   3.5 2.75 10 1.07 0.78 2500 2100
1001-B-5 120VAC, 1-PHASE, 50/60 Hz   7 5.5 10 1.07 0.78 2500 2100
1001-C-1 208-230VAC, 3-PHASE, 50/60 Hz   4.5 3.5 10 2.28 1.61 3275 2820
1001-C-2 440-460VAC, 3-PHASE, 50/60 Hz   2.8 2.4 5 2.28 1.61 3275 2820
1001-C-3 380-400VAC, 3-PHASE, 50 Hz   N/A 2.3 5 N/A 1.4 2740 2300
1001-C-4 230VAC, 1-PHASE, 50/60 Hz   7.6 5.4 10 2.28 1.61 3275 2820
1001-C-5 120VAC, 1-PHASE, 50/60 Hz   15.2 10.8 20 2.28 1.61 3275 2820
1001-D-1 120VAC, 1-PHASE, 50/60 Hz   2.5 1.85 5   0.36 0.3 1500 1250
1001-D-2 230VAC, 1-PHASE, 50/60 Hz   1.2 1 2-5   0.36 0.3 1500 1250
3) Nominal Max. Initial Flow - No External Static Pressure, 30% ASHRAE Prefilter.
    (Ask For Additional Engineering External Static Pressure vs. Flow Data)
4) Maximum Recommended Flow